Ctlsys
practices on the BACnet Energy Meter, BACnet Energy Submeter. Ctlsys energy meter has a worked on BACnet
communication module especially expected to monitor and gather continuous
revenue grade electrical data for building control and computerization
applications. The meter demonstrates various vitality parameters, for instance,
voltage, ampere, power factor, harmonic bends, vitality and request information
making it ideal for three-stage, two-phase and single stage systems to track
vitality usage and patterns. The BACnet Energy sub
meter (MS/TP) is a very effective vitality and power metering answer for
building-automation systems requiring the BACnet correspondences tradition. The
new meter supplements the Association's Modbussub meters and LonWorks sub meters, engaging any
building-automation system steady receptiveness to electrical estimations
including power, vitality, voltage, current, and power factor.
Different Features
• Small frame considers for basic foundation inside most
electrical sheets.
• Pluggable screw terminals for straightforward wiring
• 0.5% precision ostensible
• True RMS control smooth with driving or slacking power
factor and sliced or twisted waveforms
• Measure variable speed
drive pumps and motors
• Safe CT's (present Transformers),
yield 0.333 Vac at evaluated current.
•Split center CTs for speedy Foundation
•Solid center CTs are more affordable and abstain from
altering
•Custom and standard Bus Bar measured CTs
Know that the DTS-310 Modbus sub-meter is a high accuracy
gadget. For best execution purchase high exactness CTs, for example, the LNxF
Series (0.2%), the 4LSF (0.5%) or the SCT-125H (0.5%). Precision is just on a
par with the weakest connection. Another famous choice, but
"standard" 1% precision, is to combine the DTS-310 with one of Magne lab's Rogowski coils.
Components
• Line-controlled
single/three stage vitality sub-meter with auto-topology recognition
• Class 0.2
Energy Meter (ANSI C12.20) – "Revenue grade."
• Bi-directional
for sustainable frameworks (Net metering)
• Multiple
Connectivity Options
•Embedded Ethernet connectivity alternative for use with
Modbus/TCP, BACnet/IP, SNMP or DNP 3.0
•RS-485 connectivity alternative – Modbus RTU or BACnet
MS/TP
• Communications setting using
DIP switches for Modbus RTU
• Color coded, pluggable availability
• Compact DIN rail design
• User configurable utilizing DTS Config programming
• User-perceptible Modbus enlist region
• Sunspec Alliance confirmed
• Designed and Manufactured in the USA. Conforms to Buy
American Provisions of ARRA Section 1605
LonWorks Sub-Meter
Know that the DTS-310 LonWorks sub-meter is a high exactness
gadget. You might need to purchase high precision CTs, for example, the
SCT-075H or the SCT-125H (accuracy is even good when
the connection is weak). Another prominent choice, yet
"standard" 1% accuracy, is to combine the DTS-310 with one of Magne lab's Rogowski coils.
Various Features
• Line-controlled single/three stage vitality sub-meter with
auto-topology recognition
• Class 0.2 Energy Meter (ANSI C12.20) – "Revenue grade."
• Bi-directional for sustainable frameworks (Net metering)
• Multiple Connectivity Options
•Embedded Ethernet connectivity alternative for use with
Modbus/TCP, BACnet/IP, SNMP or DNP 3.0
•RS-485 connectivity alternative – Modbus RTU or BACnet
MS/TP
• Communications setting using
DIP switches for Modbus RTU
• Color coded, pluggable availability
• Compact DIN rail design
• User configurable utilizing DTS Config programming
• User-quantifiable Modbus enlist zone
• Sunspec
Alliance confirmed
No comments: